A gas tankless water heater burns fuel hotter and cleaner than a tank unit, and the exhaust that comes out is cooler and wetter. That changes what the vent has to be. A vent that worked for your old tank often cannot be reused, and that is a surprise on the quote for many people.
This guide explains why venting changes, what the main vent types are and how the vent path affects the job.
Why venting is different
Tank heaters exhaust through a metal flue that rises by buoyancy. Many high efficiency tankless units extract so much heat that the exhaust is cool enough to condense, and they push it out with a fan. That allows plastic vent pipe, but it also requires correct slope so condensation drains back to the unit, and a drain for that condensate.
Types of tankless venting
| Type. | How it works. | Keep in mind. |
|---|---|---|
| Direct vent, two pipes. | One pipe brings in outside air and one sends exhaust out. | Two penetrations through the wall or roof. |
| Direct vent, concentric. | A pipe inside a pipe does both jobs. | One penetration, special fittings. |
| Power vent, room air. | Uses air from the room and a fan to exhaust. | Needs enough combustion air in the space. |
The right type depends on the unit and the location. The maker's installation manual sets the allowed materials, lengths and clearances, and the plumber follows it.
What affects the vent work
Distance to the outside.
A short run through an exterior wall is the simplest.
Route.
Each elbow reduces the allowed length, so a complicated path limits options.
Clearances.
Windows, doors, air intakes and property lines set minimum distances.
Condensate drain.
The unit needs a safe drain for acidic condensate, often with a neutralizer.
Questions about tankless venting?
Call and describe the location. The plumber can tell you what the vent will need.
Plan the vent before you buy
Ask the plumber to look at where the unit will mount and how the vent would run before you choose a model. A unit that suits the space can save a lot of work. For the wider picture, read tankless water heater service and water heater installation.
Materials that go in the vent
Vent material is not interchangeable. Some units call for stainless steel, some allow polypropylene or PVC and some allow CPVC. Using the wrong material can void the warranty and may be unsafe. The installation manual lists what the maker allows, and the plumber follows it, including the primer and cement for plastic joints.
Termination and clearances
Where the vent exits the house matters as much as the pipe. Terminations must sit a set distance from windows, doors, gas meters and air intakes, and above the likely flood line where possible. Because south Louisiana homes sit low, check how high the exit is above the ground, since water or debris at the outlet can cause trouble.
Hurricane season adds a practical point. A wall termination that faces prevailing wind may need a protective hood or a different location, and the plumber can suggest one that fits the unit's rules.
Who should plan the vent
The plumber, not the retailer, should plan the vent. A site visit shows the wall construction, the distance to an outside wall and what sits near the exit. Ask the plumber to put the vent plan in the quote, with the pipe material, the approximate length and the number of elbows. A plan on paper makes it easier to compare quotes and to confirm the job meets the manual and the code.
Rules and conditions that affect venting in New Iberia
The City of New Iberia Permit and Inspection Department states that a permit must be obtained for any and all work, including plumbing and mechanical. Venting is part of that. Call (337) 369-2354 to learn what applies.
Plumbing requirements in Louisiana are published as part of the Louisiana State Uniform Construction Code, according to the Louisiana Department of Health. A plumber should follow the code and the manufacturer's manual together.
Source types: City of New Iberia permit page and Louisiana Department of Health plumbing page.
Where we work
We install tankless units and vents in New Iberia and in Delcambre and St. Martinville, among other towns.
Sources behind this page
Vent materials, length limits and clearances come from the maker's installation manual, which is the standard to follow alongside the Louisiana State Uniform Construction Code.
Questions homeowners ask
Usually not. The exhaust conditions are different, and the vent materials and sizes are set by the manufacturer. The plumber checks the manual.
High efficiency units cool the exhaust enough that water vapor condenses. That condensate is acidic and needs a safe path to a drain.
That depends on the unit and the pipe size. Each elbow shortens the allowed length. The installation manual lists the limits.
The City of New Iberia Permit and Inspection Department handles permits at (337) 369-2354, and state plumbing requirements are part of the Louisiana State Uniform Construction Code. The manufacturer's manual also sets limits.